Reflex 105 Conventional Flue User Installation Manual
10
3.13 Replace the screws. As the screws are tightened the glass
frame is pulled down against the hooks and forms a seal.
Replace ALL of the securing screws ensuring that a
screw is present in all xing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
3.14 Replace the lower trim.
3.15 Replace the 2 magnetic side trims.
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
PANEL IS REMOVED OR BROKEN.
3.16 Replace the decorative front by referring to the separate
instructions supplied with the front.
4. Oxygen Depletion Sensor
The appliance is tted with an oxygen sensitive pilot system
that will act to cut off the gas supply to the appliance should
the oxygen in the room fall below its normal level. If the
appliance is turned off by this device it usually indicates
that there is a problem with the ue system, this should be
inspected by a qualied engineer.
DO NOT ATTEMPT TO USE THE APPLIANCE UNTIL AN
ENGINEER SAYS IT IS SAFE TO DO SO.
THIS DEVICE IS NOT A SUBSTITUTE FOR AN
INDEPENDENTLY MOUNTED CARBON MONOXIDE
DETECTOR.
5. Flame Failure Device
5.1 This is a safety feature incorporated on this appliance
which automatically switches off the gas supply if the pilot
goes out and fails to heat the thermocouple.
IF THIS OCCURS DO NOT ATTEMPT TO RELIGHT THE
APPLIANCE FOR 3 MINUTES.
6. Running In
6.1 During initial use of a new Gazco appliance a strong
odour will be encountered as various surface coatings
become hot for the rst time. Although these odours are
harmless it is recommended that the appliance is operated
on maximum for 4 to 8 hours in order to fully burn off
these coatings. After this period the odours should then
disappear.
If the odours persist, please contact your installer for
advice.
6.2 During the rst few hours of burning there may be
discolouration of the ames. This will also disappear after a
short period of use.
User Instructions
7. Servicing
7.1 The appliance must be serviced every 12 months by a
qualied Gas Engineer. In all correspondence always quote
the Model number and the Serial number which may be
found on the Commissioning Checklist (Page 3).
8. Ventilation
8.1 Any purpose provided ventilation should be checked
periodically to ensure that it is free from obstruction.
9. Installation Details
9.1 Your installer should have completed the commissioning
sheet at the front of this book. This records the essential
installation details of the appliance. In all correspondence
always quote the Model number and Serial number.
10. Hot Surfaces
10.1 Parts of this appliance become hot during normal use.
10.2 Regard all parts of the appliance as a working surface.
10.3 Provide a suitable re guard to protect young children and
the inrm.
= Hot
Surface
9
11. Appliance will not light
If you cannot light the appliance:
11.1 Check and change the batteries in the remote handset.
11.2 Consult your Gazco retailer or installer if the appliance still
does not light.