Reflex 105 Balanced Flue User Installation Manual

45
Servicing Instructions - Replacing Parts
12. Control Box
12.1 To replace the Control Box first remove the Main Control
Assembly, see Section 4.
12.2 Cut the cable tie holding the Ignition lead and the
Thermocurrent cables.
12.3 Disconnect the Module and Solenoid leads from the Control
Box, see Diagram 34.
34
Wi-Fi Lead (if fitted)
Solenoid
Lead
Module
Lead
8-way Cable
If fitted disconnect the Wi-Fi Lead.
Note: The Wi-Fi lead is loose when removed, ensure the
lead is not misplaced whilst servicing.
12.4 Remove the Ignition Lead. The Control Box is held on by
Velcro pads.
12.5 Remove the 2 screws to remove the 2 Interrupter Leads.
12.6 Remove the 8 way cable from the Control Box.
8 Way
Cable
Interrupter Leads
Ignition lead
LED Lead
35
Module
Lead
Solenoid
Lead
Thermocouple
Pilot Pipe
Control
Box
Module
Solenoid
12.7 Replace in reverse order.
After replacing the Control Box ensure that all cable ties
and connections are refitted, see Diagram 35.
12.8 After replacing the Control Box you will need to reprogram
the handset.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code
is set. If there is a single long signal the code learning
sequence has failed or the wiring is incorrect.
Note: When pressing the DOWN button on the handset
if two beeps are not heard:
Release the DOWN button and CONN will be displayed
on the handset screen. An 8 second count will
start on the handset screen followed by two short beeps
conrming the new code is set. If there is a single long
signal the code learning sequence has failed or the
wiring is incorrect.
13. Fuel Bed Injectors
This appliance has 8 Fuel Bed Injectors.
NOTE: The injectors are not identical, see Page 12.
TO ENSURE CORRECT ASSEMBLY REPLACE EACH
INJECTOR INDIVIDUALLY.
13.1 Remove the Log Burners and Mesh Tray,
see Section 4.
13.2 Remove the 2 nuts and lock washers from each Burner
Bracket, see Diagram 36.
36
Remove the Brackets.
13.3 Remove the Gaskets, see Diagram 37.
37