Reflex 105 Balanced Flue User Installation Manual

44
Servicing Instructions - Replacing Parts
8a. Electrode
8.5 Pull the ignition lead off the electrode and undo the
retaining nut, see Diagram 31, arrow A.
31
A
B
C
8.6 Replace with a new electrode. Do not over-tighten the nut;
this could break the component.
8.7 Replace the ignition lead.
8b. Pilot Injector
8.8 With the pilot assembly removed, undo the nut to drop the
injector out from the burner, see Diagram 31, arrow B.
8c. Thermocouple
8.9 Undo the brass nut to remove the thermocouple from the
pilot burner unit, see Diagram 31, arrow C.
9. Ignition Lead
9.1 Unplug the Ignition lead from the control box, see
Diagram 32.
Ignition Lead
32
9.2 Carefully cut cable ties from the vidaflex and disconnect
the lead from the electrode.
IMPORTANT Ensure not to cut the cables.
NOTE: When replacing, ensure the ignition lead does not
run across the control box.
10. Gas Valve
To change the gas valve:
10.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
10.2 Disconnect the Gas Inlet Pipe, see Diagram 33, Arrow A.
10.3 Disconnect the Gas Outlet Pipe, see Diagram 33, Arrow B.
10.4 Disconnect the Pilot Pipe, see Diagram 33, Arrow C.
10.5 Disconnect the Thermocouple, Thermocurrent Wires and
the Interrupter Block, see Diagram 33, Arrow D.
10.6 Remove the Eight Wire Loom, see Diagram 33, Arrow E.
There is an access hole in the top of the Control Bracket to
release the locking tab.
C
D
A
B
E
33
Screw
Screw
10.7 Remove the 2 screws securing the Valve to the support
bracket and withdraw the Valve.
10.8 Replace in reverse order and check for leaks.
11. Magnetic Safety Valve
11.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
11.2 Undo the Thermocouple from the Interrupter Block and
remove the 2 Interrupter Leads.
11.3 Unscrew the Interrupter Block from the back of the Valve.
11.4 Undo the silver Magnetic Valve retaining nut on the back of
the Valve.
11.5 Gently tap out the Mag Valve.
11.6 Replace with a new unit.
11.7 Reassemble in reverse order ensuring that the interrupter
leads are connected correctly with the blue tag lead furthest
away from the gas valve body.
11.8 Check for leaks.