Reflex 105 Balanced Flue User Installation Manual
37
PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE
Ensure there is no debris around the pilot assembly,
(e.g. soot etc.) Check for uff in the pilot aeration hole.
See Section 8 in the Replacing Parts section.
Problem is with the
pipe work or
ttings which lead
to the appliance.
Correct
and retry.
Is thermocouple
connection good
in back of valve?
Replace pilot unit.
Will pilot
stay alight?
Change mag
unit.
Is the pilot ame the
correct length? Is
the thermocouple in
it's correct position
in the pilot bracket.
See Replacing Parts,
Section 8.
Clean or change
the pilot injector.
Will pilot
stay alight?
With the pilot
running is the gas
pressure as stated on
the data badge?
With the appliance
running on full is the
gas at
the pressure stated
on the data badge?
Run for 3 mins,
turn off, time interval
until mag unit shuts
with a click. Is this
greater than 7
seconds?
Run for 3 mins, turn
off, time interval until
mag unit shuts with
a click. Is this greater
than 7 seconds?
Tighten the
connection and retry.
No
No
No
No
No
No
Yes
SYSTEM OK
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Light the pilot using either the handset or the touch pad (if applicable).
FLAME FAILURE FUNCTIONAL CHECK 3
IGNITION FUNCTIONAL CHECK 2
NO SPARK
Ensure there is no debris around the pilot assembly,
(e.g. soot etc.) which could short the spark, clean the area.
Consult the users
instructions, retry.
From Ignition Fault
Finding Chart 1.
Is the gap between
electrode and
thermocouple 4mm?
Has ignition lead
become detached or is
connection poor?
Remove the ignition lead
from electrode. With insulated
pliers. Hold the tip 4mm from the
pilot pipe work, is there a spark
when the system is operated?
Has the ignition lead
become detached from the
control box?
Replace the lead, retry.
Correct and retry.
Check handset batteries are OK.
Replace if required.
Check handset is on manual.
Check if handset lock is off.
Is the control system being
operated correctly?
Reset Gap.
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Replace the electrode.
Replace the ignition
lead and retry.
Is the ue working?
Rectify ue.
No
Yes
Yes
Fault Finding Charts
Servicing Instructions










