1. Servicing Requirements
IMPORTANT – The glass panel on this appliance should be
checked for any signs of damage on the front face of the glass
panel (scratches, scores, cracks or other surface defects). If
damage is observed, the glass panel must be replaced and the
appliance must not be used until a replacement is installed.
Under no circumstances should the appliance be used if
any damage is observed. Please isolate the appliance until
a replacement glass panel has been obtained and installed.
Replacement glass panels can be purchased from Gazco via
the retailer from which the appliance was purchased or any
other Gazco distributor.
This appliance must be serviced at least once a year by a
competent person.
All tests must be carried out in accordance with the current Gas
Safe recommendations.
1.1 Before Testing:
— Conduct a gas soundness test for the property ensuring
there are no leaks before servicing.
— Check the operation of the appliance before testing.
1.2 Special checks:
— Clean the burner using a vacuum cleaner with a soft
brush attachment. Ensure all debris is removed from the
burner ports.
— Clean away lint or uff from the pilot.
— Clean away lint or uff from under the burner.
— Check the spark gap on the pilot is correct.
— Check that the Pilot ignites correctly and Main Burner
cross lights smoothly.
— Ensure that the glass frame is secured correctly and that
all retaining screws are in place.
1.3 Correct any faults found during the initial test.
1.4 Re-commission the appliance in accordance with
Commissioning Procedures of these instructions.
1.5 Advise the customer of any remedial work undertaken.
Symptom Cause Remedy
Frequent beeps for 3
seconds after operation
request
Loose/damaged wire
Check interrupter
block and wires
No ignition, no tone,
motor turns slightly
when operated
Receiver board
damaged
Replace receiver
No pilot ame and
control continues to
spark
Thermocouple circuit
wired incorrectly
Correct wiring
Pilot lights, control
continues to spark,
valve shuts down after
10 - 30 seconds
1. No spark at pilot
burner
2. Loose/damaged
wire
1. Rectify spark at
pilot burner
2. Check
interrupter and
wires
Rear burner can not be
turned off - valve can be
heard to operate.
Faulty Solenoid
Valve
Replace Solenoid
Valve
Rear burner can not be
turned off - no beep or
noise from solenoid
1. Faulty wire/ wire
not connected
2. Faulty receiver
1. Replace wire/
solenoid
2. Replace receiver
Electronic Control Valve Fault Analysis
Servicing Instructions
Servicing/Fault Finding Charts