Reflex 105 Balanced Flue User Installation Manual
22
Installation Instructions
5. Removing the Main Control Assembly
The Main Control Assembly will need to be removed to
install the gas supply.
5.1 Remove the 4 screws from the front of the Mesh Tray,
see Diagram 8.
8
Rear Screws
Front Screws
5.2 Loosen the 3 screws at the rear of the Mesh Tray, see
Diagram 8.
5.3 Slide the Mesh Tray forward slightly to disengage from the
rear screws and carefully lift over the Log Burner Brackets,
Pilot and Cross Lighter.
5.4 Remove through the front of the appliance.
5.5 Remove the 6 screws to remove the Access Panel,
see Diagram 9.
9
Screws
5.6 Remove the screw from the module bracket and carefully lift
to remove, see Diagram 10.
10
Screw
5.7 Disconnect the Mains Lead Plug, the LED leads and
the receiver lead from the Module and the Wi-Fi box (if
installed), see Diagram 11.
DO NOT REMOVE THE WIRES FROM THE PLUG.
11
LED wires
Module wires
5.8 Remove the remaining screws securing the Main Control
Assembly to the rebox, see Diagram 12.
12
5.9 Lift the rear of the Main Control Assembly and rotate
upwards slightly to clear the gas valve and remove through
the front of the appliance.
NOTE: Take care not to catch any loose wiring previously
disconnected against the front edge of the rebox.
Place carefully to one side.
5.10 The gas supply enters through the Silicone Panel located
on the left-hand rear of the outer box; this will need to be slit
with a sharp knife prior to passing the supply pipe through,
see Diagram 13.
13
Note: The Isolation Elbow needs to be attached to the gas
pipe before installation.