Reflex 105 Balanced Flue User Installation Manual
20
Installation Instructions
1. Safety Precautions
1.1 For your own and other’s safety, you must install this
appliance according to local and national codes of practice.
Failure to install the appliance correctly could lead to
prosecution. Read these instructions before installing
and using this appliance.
1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
1.4 Keep all plastic bags away from young children.
1.5 Do not place any object on or near to the appliance and
allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT
IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
1.6 The appliance is tted with an oxygen sensitive pilot that will
act to cut off the gas supply to the appliance in the event of
incorrect operation of the ue.
If the system acts to shut off the gas supply, this indicates
that there is insufcient ue pull. Continued operation of this
safety device means that there may be a serious problem
with the ue system, and this should be inspected by a
qualied gas engineer. Do not use the appliance until an
engineer says it is safe to do so.
The oxygen sensitive pilot must not be tampered with. Use
only genuine Gazco replacement parts when servicing the
appliance - refer to Servicing section.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF
THE MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF USE.
FOR DETAILS OF CHANGING BETWEEN GAS
TYPES REFER TO SERVICING, SECTION 15,
REPLACING PARTS.
Unpacking
1.7 Remove the appliance from its packaging, and check that it
is complete and undamaged.
Put the loose ceramic parts to one side so that they are not
damaged during installation.
2. Installation of the Appliance
2.1 This appliance can be installed in 2 different ways:
1) Builder’s opening with an Edge nish.
2) Studwork with an Edge nish.
3. Flue Assembly
3.1 See Site Requirements, Section 2, Flue Options.
TAKE CARE WHEN MARKING OUT FOR THE FLUE AS
IT IS DIFFICULT TO MOVE AFTER INSTALLATION. IF A
RESTRICTOR IS REQUIRED FIT THIS BETWEEN THE
SMALL OUTLET SPIGOT AND THE AIR DUCT, SEE
DIAGRAM 1. REFER TO TECHNICAL SPECIFICATIONS
FOR RESTRICTOR SIZE.
1
3.2 A 152mm (6") diameter hole in the wall is required to install
the ue. This can be achieved by using either:
a) Core drill
b) Hammer and chisel
3.3 Drill small holes around the circumference when using
method b). Make good both ends of the hole.
3.4 Allow enough room either above or to the side of the
appliance to assemble the ue on top.
3.5 Assemble a horizontal ue in the following order:
— Vertical section
— 90° elbow
— Horizontal plus terminal
3.6 Support the opening of a masonry installation with a lintel.
3.7 Only the horizontal terminal section can be reduced in size.
To nd the length:
3.8 Measure from the outside of the wall to the stop on the
90° elbow.
3.9 Add 10mm to the outlet end.
3.10 Measure from the edge of the slots closest to the wall.