Reflex 105 Balanced Flue User Installation Manual

16
Installation Instructions
2. Flue Options
2A. Top Flue Up and Out Kit
(999-026/999-026AN)
2a
Start of bend to centre line of horizontal ue 170mm. Centre
line of vertical ue to end of bend 220mm.
2.1 Vertical from the top of the appliance then horizontally out,
see Diagram 2a. The basic kit comprises:
1 x 1000mm terminal length
1 x 200mm vertical length
1 x 90 degree elbow
1 x Wall plate
1 x 60mm restrictor
1 x 70mm restrictor
4 x Fixing screw
This kit provides the minimum materials. Extra lengths can
be added to the vertical and horizontal sections;
see Section 3.
Refer to Installation Instructions, Technical Specication on
page 12 to identify when to use a restrictor.
If a vertical height of 1000mm is to be used then a Rear
Terminal must be tted, see Section 2b.
2b
2B. Top Flue Up and Out Terminal Kit
(999-044/999-044AN)
NOTE: ONLY USE WITH VERTICAL LENGTH OF
1000MM AND HORIZONTAL LENGTH OF UP TO 600MM.
2c
Start of bend to centre line of horizontal ue 170mm. Centre
line of vertical ue to end of bend 220mm.
2.2 Vertical from the top of the appliance then horizontally out,
see Diagram 2c. The basic kit comprises:
1 x 90 degree elbow
1 x 1000mm terminal length
1 x Wall plate
4 x Fixing screw
Refer to Installation Instructions, Technical Specication on
page 12 to identify when to use a restrictor.
If a vertical height of 1000mm is to be used then a Rear
Terminal must be tted.
2d
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site.
Site Requirements