Reflex 105 Balanced Flue User Installation Manual
11
Installation Instructions
Model
Gas
CAT.
Gas Type
Working
Pressure
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Reex 105 I
2H
Nat Gas G20 19mb 1.14 12.0 5.6 GB, IE
Efciency Class 1 - 92 % / NO
x
Class 4
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm Ø
Gas Inlet Connection Size Ø 8mm
Technical Specification
Covering the following models:
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 82.89%. The test data has been certied by Kiwa Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 25°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
Aeration Table
NOTE: Aeration Holes are in each leg of the burners. These holes are different sizes at the Front and Back for each individual leg.
Reex 105
Nat Gas 191-199
FRONT
Nat Gas 4.5 Ø
FRONT
Nat Gas 4.0 Ø
FRONT
Nat Gas 4.0 Ø
*(X2) indicates that a
hole is necessary in
each side of the leg.
FRONT
Nat Gas 4.5 Ø
REAR
Nat Gas 5.0 Ø (X2)*
REAR
Nat Gas 6.0 Ø (X2)*
REAR
Nat Gas 6.0 Ø
REAR
Nat Gas 4.5 Ø