Reflex 105 Balanced Flue User Installation Manual
10
User Instructions
3.13 Replace the screws. As the screws are tightened the glass
frame is pulled down against the hooks and forms a seal.
Replace ALL of the securing screws ensuring that a
screw is present in all xing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
3.14 Replace the lower trim.
3.15 Replace the 2 magnetic side trims.
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
PANEL IS REMOVED OR BROKEN.
3.16 Replace the decorative front by referring to the separate
instructions supplied with the front.
4. Flame Failure Device
4.1 This is a safety feature incorporated on this appliance which
automatically switches off the gas supply if the pilot goes
out and fails to heat the thermocouple.
IF THIS OCCURS DO NOT ATTEMPT TO RELIGHT THE
APPLIANCE FOR 3 MINUTES.
5. Running In
5.1 During initial use of a new Gazco appliance a strong odour
will be encountered as various surface coatings become hot
for the rst time. Although these odours are harmless it is
recommended that the appliance is operated on maximum
for 4 to 8 hours in order to fully burn off these coatings. After
this period the odours should then disappear.
If the odours persist, please contact your installer for advice.
5.2 During the rst few hours of burning there may be
discolouration of the ames. This will also disappear after a
short period of use.
6. Servicing
6.1 The appliance must be serviced every 12 months by a
qualied Gas Engineer. In all correspondence always quote
the Model number and the Serial number which may be
found on the Commissioning Checklist (Page 3).
7. Ventilation
7.1 This appliance requires no additional ventilation to the room.
7.2 For Installation ventilation, see Site Requirements.
8. Installation Details
8.1 Your installer should have completed the commissioning
sheet at the front of this book. This records the essential
installation details of the appliance. In all correspondence
always quote the Model number and Serial number.
9. Hot Surfaces
9.1 Parts of this appliance become hot during normal use.
9.2 Regard all parts of the appliance as a working surface.
9.3 Provide a suitable re guard to protect young children and
the inrm.
= Hot
Surface
9
10. Appliance will not light
If you cannot light the appliance:
10.1 Check and change the batteries in the remote handset.
10.2 Consult your Gazco retailer or installer if the appliance still
does not light.