Reflex 105 Balanced Flue Installation Instructions
7
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
Covering the following models:
Reex 105
Nat Gas 191-199
LPG 191-714
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 82.9%. The test data has been certied by Kiwa Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 25°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
Model
Gas
CAT.
Gas Type
Working
Pressure
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Reex 105 I
2H
Nat Gas G20 19mb 1.14 12.0 5.6
GB, IE
Reex 105 I
3+
Propane G31 36mb 0.44 12.0 5.6
Efciency Class 1 - 92 % / NO
x
Class 4
Flue Outlet Size Ø 130mm
Flue Inlet Size Ø 200mm
Gas Inlet Connection Size Ø 8mm
Restrictor Tables
RESTRICTOR REQUIREMENT - VERTICAL & HORIZONTAL FLUE SPECIFICATION
Reex 105
Vertical ue height from top of appliance Horizontal length Restrictor size
1000mm - 1999mm up to 3500mm N/A
2000mm - 3000mmm up to 6500mm N/A
TOP EXIT - VERTICAL ONLY INCLUDING OFFSET (8" with 6" adapter)
Vertical ue height from top
of appliance
Restrictor size
1500mm - 1999mm 75mm
2000mm - 4999mm 70mm
5000mm - 10000mm 60mm