Reflex 105 Balanced Flue Installation Instructions

7
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
Covering the following models:
Reex 105
Nat Gas 191-199
LPG 191-714
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 82.9%. The test data has been certied by Kiwa Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 25°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
Model
Gas
CAT.
Gas Type
Working
Pressure
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Reex 105 I
2H
Nat Gas G20 19mb 1.14 12.0 5.6
GB, IE
Reex 105 I
3+
Propane G31 36mb 0.44 12.0 5.6
Efciency Class 1 - 92 % / NO
x
Class 4
Flue Outlet Size Ø 130mm
Flue Inlet Size Ø 200mm
Gas Inlet Connection Size Ø 8mm
Restrictor Tables
RESTRICTOR REQUIREMENT - VERTICAL & HORIZONTAL FLUE SPECIFICATION
Reex 105
Vertical ue height from top of appliance Horizontal length Restrictor size
1000mm - 1999mm up to 3500mm N/A
2000mm - 3000mmm up to 6500mm N/A
TOP EXIT - VERTICAL ONLY INCLUDING OFFSET (8" with 6" adapter)
Vertical ue height from top
of appliance
Restrictor size
1500mm - 1999mm 75mm
2000mm - 4999mm 70mm
5000mm - 10000mm 60mm