Reflex 105 Balanced Flue Installation Instructions

38
Turn the Main Control Assembly over.
Withdraw the Cross Lighting bar from the Control Assembly.
The Injector is screwed into the bottom of the bar.
3
Replace with the correct size Injector and ret all components in the
reverse order.
Ensure the left and right hand sides of the Burner engages in the
bracket slots.
NOTE: The LH bracket is part of the Pilot bracket.
LH Bracket
RH Bracket
4
Check for leaks.
GAS VALVE
To change the gas valve:
Remove the Log Burners and Main Control Assembly.
Disconnect the Gas Inlet Pipe, Arrow A.
Disconnect the Gas Outlet Pipe, Arrow B.
Disconnect the Pilot Pipe, Arrow C.
Disconnect the Thermocouple, Thermocurrent Wires and the
Interrupter Block, Arrow D.
Remove the Eight Wire Loom, Arrow E.
There is an access hole abovce the cable plug oin the valve.
Insert a small screwdriver to release the locking tab.
C
D
A
B
E
Screw
Screw
Remove the 2 screws securing the Valve to the support bracket and
withdraw the Valve.
Replace in reverse order and check for leaks.
MAGNETIC SAFETY VALVE
Remove the Log Burners and Main Control Assembly.
Undo the Thermocouple from the Interrupter Block and remove the
2 Interrupter Leads.
Unscrew the Interrupter Block from the back of the Valve.
Undo the silver Magnetic Valve retaining nut on the back of the
Valve.
Gently tap out the Mag Valve.
Replace with a new unit.
Reassemble in reverse order ensuring that the interrupter leads are
connected correctly with the blue tag lead furthest away from the
gas valve body.
Check for leaks.
SERVICING INSTRUCTIONS