Reflex 105 Balanced Flue Installation Instructions

32
SERVICING INSTRUCTIONS
GENERAL
All main components can be replaced without removing the
appliance from its installation.
DISCONNECT MAINS ELECTRICAL SUPPLY AT THE
ACCESSIBLE PLUG OR DEDICATED SWITCH BEFORE
SERVICING THE APPLIANCE.
IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE APPLIANCE
IS TURNED OFF AT THE ISOLATION DEVICE BEFORE
PROCEEDING FURTHER.
It will be necessary to remove the burners and the fuel bed before
any of the main components can be serviced.
The Power Module and the Wi-Fi Receiver can be serviced by
removing the decorative trim and lower glass retaining bracket.
DURING SERVICING OF THIS APPLIANCE IT MAY
BE NECESSARY TO CUT CABLE TIES IN ORDER TO
ACCESS AND REMOVE SOME OF THE PARTS.
THESE MUST BE REPLACED WHEN
REASSEMBLING THE APPLIANCE.
AFTER SERVICING ENSURE THAT ALL
CONNECTIONS ARE REPLACED BEFORE
REPLACING THE MESH TRAY.
REMOVING THE GLASS FRAME
Remove the glass door by removing the 2 side trims.
These are held on by magnets.
Lift out the bottom slotted trim.
Remove the 3 screws at the base of the door.
Screws
Pull up the handle at the front.
Whilst supporting the top, lift the door using the handle, up and
over the lower edge,.
1
2
When retting the glass frame ensure that the rope seal on
the back of the frame is intact.
Replace the screws. As the screws are tightened the glass frame is
pulled down against the hooks and forms a seal.
Replace ALL of the securing screws ensuring that a screw is
present in all xing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
Replace the lower trim.
Replace the 2 magnetic side trims.
NEVER OPERATE THE APPLIANCE WHEN THE GLASS PANEL
IS REMOVED OR BROKEN.
The glass frame must be retted to the appliance following
cleaning or servicing.