Reflex 105 Balanced Flue Installation Instructions
24
INSTALLATION INSTRUCTIONS
18
19
≈25 %
20
21
NOTE: ENSURE THAT THE LOGS ARE POSITIONED
AS ABOVE. ONLY USE THE CORRECT AMOUNT OF
LOGS AS SPECIFIED IN THE DIAGRAMS.
COMPLETION OF ASSEMBLY
1
Ensure that the rope seal on
the back of the glass frame is
intact.
Push the handle down.
Replace the screws. As the screws are tightened the glass frame
is pulled down against the hooks and forms a seal.
Replace ALL of the securing screws ensuring that a screw is
present in all xing slots.
2
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
PANELS ARE LOOSE, DAMAGED, OR MISSING.
3