Reflex 105 Balanced Flue Installation Instructions
20
INSTALLATION INSTRUCTIONS
7
8
9
GAS SOUNDNESS PRESSURE CHECK
Connect a suitable pressure gauge to the test point located on the
inlet tting. Turn the gas supply on.
Test Point
Remove the xing screws and loosely place the appropriate burners
onto the injectors.
Light the appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply pressure is as
stated on the databadge. Turn the appliance off. Replace the test
point screw and check the test point for leaks.
Remove the burners. Take care as the burners will be hot.
Replace the access panel, securing with the 4 screws.