Reflex 105 Balanced Flue Installation Instructions
14
INSTALLATION INSTRUCTIONS
PRE-INSTALLATION
REMOVING THE GLASS FRAME
Remove the glass door by removing the 2 side trims.
These are held on by magnets.
Lift out the bottom slotted trim.
Remove the 3 screws at the base of the door.
Screws
Pull up the handle at the front.
Whilst supporting the top, lift the door using the handle, up and
over the lower edge,.
1
2
Remove the 2 boxes from the appliance and store safely as they
contain the Log Burners and fuel effects.
REMOVING THE MAIN CONTROL
ASSEMBLY
The Main Control Assembly will need to be removed to install the
gas supply.
Remove the 4 screws from the front of the Mesh Tray.
Rear Screws
Front Screws
Loosen the 3 screws at the rear of the Mesh Tray.
Slide the Mesh Tray forward slightly to disengage from the rear
screws and carefully lift over the Log Burner Brackets, Pilot and
Cross Lighter.
Remove through the front of the appliance.
Remove the 6 screws to remove the Access Panel.
Screws
Remove the screw from the module bracket and carefully lift to
remove.
Screw