Reflex 105 Balanced Flue Installation Instructions
13
INSTALLATION INSTRUCTIONS
DISTANCE TO NON-COMBUSTIBLE OR COMBUSTIBLE
MATERIAL
TO CREATE ENOUGH CLEARANCE FOR THE TOP VENTS TO
OPEN. IT IS IMPORTANT THAT NO PART OF THE STUDWORK
(COMBUSTIBLE OR NOT) IS BUILT WITHIN 400MM OF THE
TOP OF THE BOX.
It is recommended that a marble slip or similar material is used
when tting cassette replaces into a plastered surface, in order
to allow for heat dissipation. Also allow adequate time for newly
plastered areas to dry out. Rapid drying can create cracks. If in
doubt, seek the advice of a professional plasterer.
Parts of this appliance become hot during normal use. It is therefore
recommended that a suitable re guard be used for protection of
young children and the inrm.
MASONRY INSTALLATION
Please note this appliance has been primarily designed for
studwork applications. However, there are circumstances where the
appliance could be installed in a block or brickwork replace using
different methods and materials for the nal effect.
THIS VOID MUST BE VENTED TO PREVENT HEAT BUILD UP
AROUND THE APPLIANCE.
This appliance is not suitable for installation onto a combustible
wall. Remove all combustible material from the area shown.
Create a Builders Opening in chimney breast to the required size.
Ensure that the clearances to combustible materials is maintained.
MINIMUM
CLEARANCES
TO NON
COMBUSTIBLE
MATERIAL
20mm*
150mm
12mm
20mm
20mm
200mm
20mm
50mm
5mm minimum
(without lintel)
* NOTE: It will be necessary to leave a greater rear
clearance around the plug cabling to ensure the wires
are not damaged or placed under stress following
installation.