Reflex 105 Balanced Flue Installation Instructions
12
INSTALLATION INSTRUCTIONS
APPLIANCE LOCATION
If tting this appliance with a decorative frame it
cannot be installed with the base of the appliance
less than 150mm from the oor level. The frame
requires a minimum clearance to allow air to
circulate.
If this appliance is tted less than 225mm from the
oor, then it will require a hearth to protect the oor.
The hearth should have a minimum dimension of
12mm thick, projecting 225mm in front and 150mm
either side of the appliance.
Minimum opening dimensions:.
DIMENSION Reex 105
A 1160mm
B 444mm
C 793mm
This appliance must not be installed in a room that contains a bath
or shower.
NOTE: If using natural materials for the back panel of the
replace, it is recommended that it is constructed from three or
more sections to prevent cracking. Resin based materials may
not be suitable. This appliance is an effective heat producer
and attention must be paid to the construction and nish of the
replace.
This appliance is not suitable for installation onto a combustible wall;
all combustible materials must be removed from the area shown.
1560
1160
200
793
400
1119
Decorative Surround
If tting this appliance with a decorative surround refer
to separate installation instructions supplied with the
Surround.
This appliance is designed so that non-combustible
board can be taken right up to the edge of the
ange.
Whether nishing with an edge effect or with a
decorative frame this appliance must be installed
using the Edge Installation method.
STUDWORK INSTALLATION
If a studwork installation is used (eg. wooden framework and
plasterboard), combustible parts of the studwork must not be any
closer than the minimum dimensions shown in the diagrams. NOTE:
These dimensions must be maintained even if the combustible
materials is protected by non-combustible linings.
Do not pack the void around or above the appliance with insulation
materials such as mineral wool.
The void built for the cassette must be ventilated to prevent a build-
up of heat. Vents must be tted at both high and low levels of a
minimum of 300cm² each. These vents must take cold air from the
room and return warm air back into the room.
A removable access hatch must be left in the side of the chimney
breast for future servicing and inspection of the appliance.
Build the studwork chimney breast to the desired size. Ensure that
the clearances to combustible materials is maintained.
PROTECT THE NEAREST STUDWORK WITH NON-
COMBUSTIBLE MATERIAL AND MAINTAIN THESE
DIMENSIONS AT ALL TIMES.
MINIMUM
COMBUSTIBLE
MATERIAL
CLEARANCES
400mm
100mm
150mm
12mm
100mm
200mm
200mm
200mm
Non-combustible
board
Non-combustible
board