Reflex 105 Balanced Flue Installation Instructions
11
INSTALLATION INSTRUCTIONS
FLUE OPTIONS
6" TOP FLUE VERTICAL KIT
(999-352/999-352AN)
NOTE: This product when tted with an adpater is
designed for and requires an 6" ue system. It is
essential when ordering additional parts to consult
table 2 for the relevant part numbers.
This ue is vertical from the top of the appliance.
A minimum vertical rise of 1.5m (4'92”) to a maximum of 10m
(32’10”). The basic kit comprises:
1 x 8" to 6" Adapter
1 x 500mm Length
1 x 1m Terminal Length
1 x 60mm Restrictor
1 x 70mm Restrictor
1 x 75mm Restrictor
Extra lengths may be added from table 2 in Section 3.
Fit the adapter prior to connecting the ue pipe.
200mm
This Gazco balanced ue system is designed to run
internally with only the terminal projecting from the
building.
TOP FLUE VERTICAL OFFSET
KIT (8530/8530AN)
Used with kit 999-352. A minimum rise of 500mm (191/2) is required
to the rst bend.
OPTIONAL EXTRA FLUE LENGTHS
AND BENDS
TABLE 1 - 8"
NOMINAL
LENGTH
ACTUAL
LENGTH
STAINLESS
FINISH
ANTHRACITE
FINISH
200mm 140mm 999-113 999-113AN
500mm 440mm 999-132 999-132AN
1000mm 940mm 999-177 999-177AN
Adjustable Length 999-255 999-255AN
TABLE 2 - 6"
NOMINAL
LENGTH
ACTUAL
LENGTH
STAINLESS
FINISH
ANTHRACITE
FINISH
200mm* 140mm* 8527 8527AN
500mm* 440mm* 8528 8528AN
1000mm* 940mm* 8529 8529AN
*Not including adapter dimensions
NOTE: The following areas need careful consideration.
a) Terminal positions
b) Flue supports
c) Weatherproong
d) Fire precautions
For all the above options, local and national codes of practice
must be adhered to.
IMPORTANT:
1M VERTICAL, TERMINAL AND STRAIGHT FLUE
LENGTHS MUST NOT BE CUT!