1. Commissioning
1.1 Close all doors and windows in the room.
1.2 Ignite the appliance and operate on maximum for 10
minutes.
1.3 Position a lighted smoke match just inside the draught
diverter opening at the rear of the appliance.
1.4 Check all smoke is drawn into the opening, see Diagram 1.
1
Rear of Appliance
Draft
diverter lip
Smoke match
1.5 If there is any doubt, run the appliance for a further 10
minutes, and repeat the test.
1.6 If there are any extractor fans in adjacent rooms, the test
must be repeated with the fans running on maximum and
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND
SEEK EXPERT ADVICE.
1.7 Complete the Commissioning Checklist at the front of this
manual covering:
— Thermocouple soundness checks.
This is to include ensuring the thermocouple is secure on
the pilot bracket assembly, lead connection and integrity.
— Flue checks
— Gas checks
— Log layout - ame picture
1.8 Upon completion of the commissioning and testing of the
installation and correct operation of the appliance, the
installer must instruct the user how to operate the appliance.
1.9 Guide the user through the User Instructions paying
particular attention to:
a) Regular servicing (Section 11 of the User Instructions).
b) Ventilation (Section 12 of the User Instructions) - point out
the ventilation positions where applicable.
c) Hot surfaces (Section 14 of the User Instructions).
Installation Instructions/Commissioning
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period.
10.7 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
10.8 Turn the right-hand knob to the left to main burner
setting ( ).
Adjusting the Flame height
10.9 You can now adjust the ame height and temperature using
the left-hand control knob.
10.10 Turn the left-hand knob anti-clockwise to increase the
ame height.
10.11 Turn clockwise to decrease the height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT
OR BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.