Conventional Flue

20
Installation Instructions
6. Removing the Glass
6.1 Using a screwdriver remove the 4 screws securing the
window panel to the appliance, see Diagrams 16 & 17.
Take care to support the glass when removing the screws.
Vogue Midi & Midline
16
Vogue Midi T - Midi, Midline & Highline
17
All Models
6.2 The frame can be removed by lifting the hooks clear of the
slots from the bottom of the frame and lifting away from the
appliance, see Diagram 18.
18
Vogue Midi Shown
7. Arrangement of Fuel Bed
Advice on handling and disposal
of fire ceramics
The fuel effect in this appliance are made from
Refractory Ceramic Fibre (RCF), a material which
is commonly used for this application.
Protective clothing is not required when handling
these articles, but we recommend you follow
normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your
hands before eating or drinking.
To ensure that the release of RCF bres are kept
to a minimum, during installation and servicing
a HEPA ltered vacuum is recommended to
remove any dust accumulated in and around the
appliance before and after working on it. When
servicing the appliance it is recommended that
the replaced items are not broken up, but are
sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landll site.
Excessive exposure to these materials may
cause temporary irritation to eyes, skin and
respiratory tract; wash hands thoroughly after
handling the material.
8. Log Layout
LOGS MUST BE POSITIONED ACCORDING TO THE
FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT
FLAME EFFECT.
All logs can be identied by a letter (A - D) on their
underside. Logs A and B have holes to locate each onto a
burner stud.
8.1 Ensure the burner tray is clean and free from any debris, see
Diagram 19.
Note: The burner trays are visually different, depending on
the model, but the log layouts are the same.
19
Midi/ Midi Midline Nat Gas Burner shown
(Midi/ Midi Midline
Nat Gas only)