Conventional Flue
19
Installation Instructions
4.5 Swap the ue spigot only with the Blanking Plate on the rear
of the appliance, see Diagram 10.
10
Blanking
Plate
4.6 Attach the decorative ue blanking plate support bracket to
the underside of the cast top using the screws provided.
Ensure the folded return is pressed against the cast top, see
Diagram 11.
11
4.7 Sit the decorative ue blanking plate in position,
see Diagram 12.
12
4.8 Replace the cast top. When tted properly the cast plate
should sit ush with the rear of the stove, see Diagram 13.
13
Vogue Midi Shown
5. Gas Soundness Pressure Check
This is essential to expel any debris that may block the gas
controls.
5.1 Connect the gas to the 8mm elbow on the rear of the
appliance, see Diagram 14 & 15.
Vogue Midi & Midline
14
Vogue Midi T - Midi, Midline & Highline
15
5.2 Connect a suitable pressure gauge to the test point located
on the inlet tting and turn the gas supply on. Light the
appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply
pressure is as stated on the databadge. Turn the gas off and
replace the test point screw, turn the gas on and check the
test point for leaks.