Conventional Flue

10
Installation Instructions
Technical Specification
Covering the following models:
Model
Gas
CAT.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Vogue Midi /
Vogue Midi
Midline
I
2H
Natural Gas
(G20)
20mbar 2 x 5.5mm 360 0.590 6.2 2.9
GB, IE
I
3P
Propane (G31) 37mbar 2 x 14mm 120 0.203 5.4 2.8
Vogue Midi
T - Midi /
Vogue Midi T
- Midline /
Vogue Midi T
- Highline
I
2H
Natural Gas
(G20)
20mbar 2 x 6mm 360 0.590 6.2 3.5
I
3P
Propane (G31) 37mbar 2 x 13mm 125 0.222 5.9 3.3
Vogue Midi Models - Efciency Class 2 - 76% Net
Vogue Midi T Models - Efciency Class 2 - 78% Net
Flue Size TOP/REAR EXIT 127mm ø
Gas Inlet Connection Size = 8mm ø
Minimum Flue Specication = T250/N2/0/D/1
Maximum Flue Temp = 240°C
The net efciency of these appliances have been measured as specied in EN613:2001 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 68.5% (Vogue Midi Models) & 70.3% (Vogue Midi T Models).
The test data has been certied by Kiwa Nederand BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Model
VOGUE MIDI
VOGUE MIDI T
MIDI
VOGUE MIDI
MIDLINE
VOGUE MIDI T
MIDLINE
VOGUE MIDI T
HIGHLINE
Nat Gas 563-123 563-180 563-392 563-224 563-191
LPG 563-426 563-701 563-466 563-493 563-447