Conventional Flue
10
Installation Instructions
Technical Specification
Covering the following models:
Model
Gas
CAT.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Vogue Midi /
Vogue Midi
Midline
I
2H
Natural Gas
(G20)
20mbar 2 x 5.5mm 360 0.590 6.2 2.9
GB, IE
I
3P
Propane (G31) 37mbar 2 x 14mm 120 0.203 5.4 2.8
Vogue Midi
T - Midi /
Vogue Midi T
- Midline /
Vogue Midi T
- Highline
I
2H
Natural Gas
(G20)
20mbar 2 x 6mm 360 0.590 6.2 3.5
I
3P
Propane (G31) 37mbar 2 x 13mm 125 0.222 5.9 3.3
Vogue Midi Models - Efciency Class 2 - 76% Net
Vogue Midi T Models - Efciency Class 2 - 78% Net
Flue Size TOP/REAR EXIT 127mm ø
Gas Inlet Connection Size = 8mm ø
Minimum Flue Specication = T250/N2/0/D/1
Maximum Flue Temp = 240°C
The net efciency of these appliances have been measured as specied in EN613:2001 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 68.5% (Vogue Midi Models) & 70.3% (Vogue Midi T Models).
The test data has been certied by Kiwa Nederand BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Model
VOGUE MIDI
VOGUE MIDI T
MIDI
VOGUE MIDI
MIDLINE
VOGUE MIDI T
MIDLINE
VOGUE MIDI T
HIGHLINE
Nat Gas 563-123 563-180 563-392 563-224 563-191
LPG 563-426 563-701 563-466 563-493 563-447