Gas Vision Small, Midi & Medium Dimensions (see letters on diagram)
A B C D E F G H I J K L M
Small CF
143 57 58 254 240 122 370 43 529 359 185 97 289
Small BF
†
N/A 57 58 254 240 122 370 N/A 529 379 185 N/A 289
Midi CF
143 65 50 316 241 127 415 43 605 436 208 96 311
Midi BF
173 65 50 316 241 127 415 69 605 456 208 142 311
Medium CF
143 77 64 408 274 150 535 43 677 487 268 100 353
Medium BF
173 77 64 408 274 150 535 69 677 538 268 139 353
Stove Flue Pipe
Balanced flue versions of the Gas Visions must only use the 6"
stainless steel or anthracite flue pipe. For the conventional flue version
of the Gas Vision Gazco recommends the use of 5" matt black or
gloss enamelled stove pipe. The components usually required are:
Matt Black Flue Pipe Product Code
1' Straight pipe
4500
2' Straight pipe
4501
3' Straight pipe
4502
90° Long ‘elbow’ adaptor (9" projection)
4514
Flue collar
8549
The above information is to assist in your choice of a suitable Gazco stove. This is not intended to be all the information required to install your stove. This can be obtained from your local Gazco retailer or you can download the full
installation instructions from the Gazco website at www.gazco.com
74
The Gas Vision stoves can also be placed on one of our ten stove
benches. Please see page 78 for further information.
Recommended clearances between stove and other surfaces: top 9”
(225mm), sides 6” (150mm) and rear 2” (50mm).
Gas Vision Dimensions in mm.
†
Vision Small Balanced flue is rear flue exit only
A
B
C
D*
E*
F
G
K
L
I
J
H
*Glass Viewing Area
M
A B C D E F G H I J K L M
Small
N/A 57 58 254 240 122 370 N/A 555 N/A N/A N/A 299
Midi
N/A 65 50 316 241 127 415 N/A 604 N/A N/A N/A 320
Medium
N/A 77 64 408 274 152 535 N/A 676 N/A N/A N/A 363
Electric Vision Dimensions (see letters on diagram)
Product
Code
Model
CF/
BF
Fuel
Effect
Lining
Fuel
Type
Flue
Exit
Heat
Input
(kW)
Heat
Output
(kW)
Efficiency
Energy
Efficiency
Class
Gas Vision Small - Manual & Upgradeable Remote Options
526-013
Small CF Logs Vermiculite Nat. Gas Rear 3.30 2.30 76%
E
#
526-643
Small CF Logs Vermiculite LPG Rear 3.20 2.20 76%
E
#
526-021
Small CF Logs Vermiculite Nat Gas Top 3.30 2.30 76%
E
#
526-656
Small CF Logs Vermiculite LPG Top 3.20 2.20 76%
E
#
526-046
Small BF Logs Vermiculite Nat. Gas Rear 3.20 2.50 85.1%
C
#
526-405
Small BF Logs Vermiculite LPG Rear 3.10 2.40 85.1%
C
#
Gas Vision Midi - Manual & Upgradeable Remote Options
526-065
Midi CF Logs Vermiculite Nat.Gas Rear 4.55 3.10 75%
E
#
526-417
Midi CF Logs Vermiculite LPG Rear 4.35 3.00 75%
E
#
526-077
Midi CF Logs Vermiculite Nat.Gas Top 4.55 3.10 75%
E
#
526-440
Midi CF Logs Vermiculite LPG Top 4.35 3.00 75%
E
#
526-100
Midi BF Logs Vermiculite Nat. Gas Rear 4.30 3.70 95.4%
A
#
526-471
Midi BF Logs Vermiculite LPG Rear 4.30 3.80 95.4%
A
#
526-109
Midi BF Logs Vermiculite Nat. Gas Top 4.30 3.70 95.4%
A
#
526-486
Midi BF Logs Vermiculite LPG Top 4.30 3.80 95.4%
A
#
Gas Vision Medium - Manual & Upgradeable Remote Options
526-122
Medium CF Logs Vermiculite Nat.Gas Rear 6.60 4.60 78%
E
#
526-515
Medium CF Logs Vermiculite LPG Rear 6.70 4.80 78%
E
#
526-137
Medium CF Logs Vermiculite Nat.Gas Top 6.60 4.60 78%
E
#
526-539
Medium CF Logs Vermiculite LPG Top 6.70 4.80 78%
E
#
526-155
Medium BF Logs Vermiculite Nat. Gas Rear 6.60 5.40 90.8%
B
#
526-580
Medium BF Logs Vermiculite LPG Rear 6.60 5.50 90.8%
B
#
526-176
Medium BF Logs Vermiculite Nat Gas Top 6.60 5.40 90.8%
B
#
526-612
Medium BF Logs Vermiculite LPG Top 6.60 5.50 90.8%
B
#
Gas & Electric Vision
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8455
Standard Upgradeable Remote Control for Vision
8456
Programmable Thermostatic Upgradeable Remote
Gas Vision - Accessories
Electric Vision with Remote Control
634-680
Small - Logs - Electric - - 2.00 99% -
634-733
Midi - Logs - Electric - - 2.00 99% -
634-795
Medium - Logs - Electric - - 2.00 99% -
X
X
X
#
When upgraded with a Programmable Thermostatic Control (8456)
Weight: Vision Electric Small: 24kg. Vision Electric Midi: 28kg. Vision Electric Medium: 38kg.