Balanced Flue
7
All Models
5.4 Remove the frame to gain access to the viewing aperture
by lifting the hooks clear of the slots on the front of the
appliance, see Diagram 6.
6
5.5 Using a screwdriver remove the 4 screws securing the
window panel to the appliance, see Diagrams 7 & 8.
Take care to support the glass when removing the screws.
Vogue Midi & Midline
7
Vogue Midi, Midline & Highline T
8
5.6 The frame can be removed by lifting the hooks clear of the
slots from the bottom of the frame and lifting away from the
appliance, see Diagram 9.
9
Vogue Midi Shown
5.7 The glass frame must be retted to the appliance following
cleaning or servicing. Hold in position and secure with the
screws.
5.8 Replace ALL of the securing screws ensuring that a screw is
present in all xing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE
OR MISSING.
6. Arrangement of Fuel Bed
Advice on handling and disposal
of fire ceramics
The fuel effect in this appliance are made from
Refractory Ceramic Fibre (RCF), a material which
is commonly used for this application.
Protective clothing is not required when handling
these articles, but we recommend you follow
normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your
hands before eating or drinking.
To ensure that the release of RCF bres are kept
to a minimum, during installation and servicing
a HEPA ltered vacuum is recommended to
remove any dust accumulated in and around the
appliance before and after working on it. When
servicing the appliance it is recommended that
the replaced items are not broken up, but are
sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landll site.
Excessive exposure to these materials may
cause temporary irritation to eyes, skin and
respiratory tract; wash hands thoroughly after
handling the material.