Balanced Flue

58
Model
Vogue Midi T
Midline 3 Sided
BF NG
Vogue Midi T
Midline 3 Sided
BF LPG
Vogue Midi T
Wall Mounted
3 Sided BF NG
Vogue Midi T
Wall Mounted
3 Sided BF LPG
Vogue Midi T
Highline
3 Sided BF NG
Vogue Midi T
Highline
3 Sided BF LPG
Fuel
Space Heating Emissions (NOx) - mg / kWh
input
(GCV) 130 130 130 130 130 130
Heat
Output
Nominal Heat Output - P
nom
4.8kW 4.3kW 4.8kW 4.3kW 4.8kW 4.3kW
Minimum Heat Output (indicative) -P
min
2.9kW 2.4kW 2.9kW 2.4kW 2.9kW 2.4kW
Auxiliary
Electricity
Consumption
At Nominal Heat Output - el
max
N/A N/A N/A N/A N/A N/A
At Minimum Heat Output - el
min
N/A N/A N/A N/A N/A N/A
In Standby Mode - el
sb
N/A N/A N/A N/A N/A N/A
Useful
Efciency
Useful Efciency at nominal heat output - η
th,nom
94.3% 94.3% 94.3% 94.3% 94.3% 94.3%
Useful Efciency at minimum heat output (indicative) -
η
th,min
91.5% 91.5% 91.5% 91.5% 91.5% 91.5%
Pilot Flame
Power
requirement
Permanent Pilot Flame Power requirement (if applicable) -
P
pilot
0.200kW 0.200kW 0.200kW 0.200kW 0.200kW 0.200kW
Type of heat output/room temperature control
Electronic room temperature control + day timer Yes Yes Yes Yes Yes Yes
Other control options (multiple selections possible)
Room temperature control, with presence detection No No No No No No
Room temperature control, with open window detection No No No No No No
With distance control option No No No No No No
With adaptive start control No No No No No No
With working time limitation No No No No No No
With black bulb sensor No No No No No No
Energy Efciency Index 88.2% 88.0% 88.2% 88.0% 88.2% 88.0%
Energy Efciency Class A* A* A* A* A* A*
*When used with optional Thermostatic Control
Contact: Gazco Ltd, Osprey Road, Sowton Industrial Estate, Exeter, EX2 7JG
Information Requirement for Gaseous Fuel Local Space Heater