Balanced Flue
43
Servicing Instructions - Replacing Parts
13. Glass Side Panels -
3 Sided Models Only
To service the glass side panels, rst remove the back panel
and the side trims (see Section 4b).
13.1 Undo the four screws securing the front bracket and remove,
see Diagram 31.
31
13.2 Undo the 4 screws securing the rear bracket and remove,
see Diagram 32.
32
13.3 Replace the glass and gasket, ensuring that the printed side
is facing outwards.
14. Primary Aeration Plate
NOTE: Not all models have aeration plates.
Please refer to the Technical Specication.
14.1 To replace the primary aeration plate turn off the gas supply
at the isolation device.
14.2 Remove the burner, see Installation Instructions, Replacing
Parts, Section 5.
14.3 Undo the 2 nuts and remove the plate.
14.4 Replace with the correct size plate and secure the 2 nuts.
Ensure that the lower edge of the plate is located over the
venturi ange, see Diagram 33.
33
15. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco
retailer for further information.
It will be necessary to replace the following components:
- Top Bafe
- Burner
- Injector
- Pilot Injector
- Gas Valve
Always quote the Model number and Serial number when
ordering any spare parts.
16. Control Upgrade
See Installation Instructions, Section 2.