Balanced Flue

43
Servicing Instructions - Replacing Parts
13. Glass Side Panels -
3 Sided Models Only
To service the glass side panels, rst remove the back panel
and the side trims (see Section 4b).
13.1 Undo the four screws securing the front bracket and remove,
see Diagram 31.
31
13.2 Undo the 4 screws securing the rear bracket and remove,
see Diagram 32.
32
13.3 Replace the glass and gasket, ensuring that the printed side
is facing outwards.
14. Primary Aeration Plate
NOTE: Not all models have aeration plates.
Please refer to the Technical Specication.
14.1 To replace the primary aeration plate turn off the gas supply
at the isolation device.
14.2 Remove the burner, see Installation Instructions, Replacing
Parts, Section 5.
14.3 Undo the 2 nuts and remove the plate.
14.4 Replace with the correct size plate and secure the 2 nuts.
Ensure that the lower edge of the plate is located over the
venturi ange, see Diagram 33.
33
15. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco
retailer for further information.
It will be necessary to replace the following components:
- Top Bafe
- Burner
- Injector
- Pilot Injector
- Gas Valve
Always quote the Model number and Serial number when
ordering any spare parts.
16. Control Upgrade
See Installation Instructions, Section 2.