Balanced Flue
42
Vogue Midi & Midline T 3 Sided
27
Screws
10.7 Slide the bracket slightly to the right and pull forward to
access the valve connections.
10.8 Disconnect the 2 x 8mm and 1 x 4mm gas pipe ttings at the
back of the gas valve, see Diagram 28 (A).
10.9 Disconnect the thermocouple, see Diagram 28 (B).
28
A
A
B
C
10.10 Disconnect the ignition lead from the gas valve,
see Diagram 28 (C).
10.11 Remove the cover, see Section 8.3.
10.12 Undo the 2 screws securing the gas valve to the appliance
and remove the valve.
10.13 Replace in reverse order.
10.14 Check all joints for gas leaks and check operation of the
thermocouple and ignition lead.
Servicing Instructions - Replacing Parts
11. Magnetic Safety Valve
11.1 Turn the gas supply off at the isolation device.
11.2 Remove the gas valve, see Section 10.
11.3 Undo the magnetic valve-retaining nut from the back of the
control valve, see Diagram 29.
11.4 Gently tap out the magnetic valve and replace with a new
unit.
11.5 Replace the retaining nut and tighten.
29
11.6 Reassemble the interrupter block and leads and secure the
thermocouple connection in the rear of the gas control.
(Do not overtighten).
11.7 Turn the gas supply on and check the entire pipework and
valve joints for any leaks.
12. Main Injector
12.1 To remove the main injector turn off the gas supply at the
isolation device.
12.2 Remove the main burner, see Section 5.
12.3 Undo the compression nuts from the feed pipe and the gas
valve under the appliance.
12.4 Working from inside the rebox remove the lock nut from the
injector, see Diagram 30.
30
12.5 Extract the injector with the feed pipe from beneath the
appliance.
12.6 Holding the injector with a spanner:
12.7 Undo the feed pipe. Note the orientation of the Injector.
12.8 Re-assemble in reverse order.
12.9 Turn on the gas supply and check for leaks.