Balanced Flue
19
Installation Instructions
Site Requirements
NOTE: It is not recommended to install Midline/
Highline models on a bench.
MIDLINE & HIGHLINE MODELS
7.8 It is not necessary to site these products on a non-
combustible floor. However, for practical reasons, the floor
should be flat and solid to allow the appliance to be levelled
and secured in place.
7.9 This appliance may be situated anywhere in the room, but
due consideration should be taken to ensure that it is sited
within the constraints of the allowable flue configuration.
DO NOT INSTALL APPLIANCE ON A CARPET.
SECURING THE APPLIANCE TO THE WALL
(WALL MOUNTED MODELS ONLY)
WARNING: This appliance weighs 62kg.
The manufacturer has designed this appliance to
attach to a masonry wall and all xings supplied
reect this. If siting on a studwork wall, the xing
points must be through the timber stud and not
plasterboard. Use appropriate xings.
DO NOT attach solely to a plasterboard wall.
7.10 If installing on a studwork wall it is essential that the
batterns are located in the xing area for the wall
mounting bracket, see Diagram 8.
8
340
523
7.11 DISTANCE FROM FLOOR / HEARTH LEVEL
It is necessary to leave a minimum gap of 100mm
below the base of the wall mounted appliance to ensure
servicing access.
MINIMUM CLEARANCE
7.12 Freestanding appliances are not suitable for installation
against a combustible wall.
(NOT APPLICABLE FOR WALL MOUNTED MODELS.)
7.13 Ensure that all minimum clearances to combustible
materials are complied with, see Diagrams 9 & 10.
The specied clearances provide the minimum distance to
combustible materials. If the appliance is intended to be
installed into a non-combustible opening the clearance to the
sides and above the appliance can be reduced. However, it
is recommended that the specied clearances are maintained
irrespective of the materials used in the construction of the
opening to allow adequate air ow and access to controls.
The clearance at the rear of the appliance must always
be a minimum of 50mm (NOT APPLICABLE FOR WALL
MOUNTED MODELS).
A
B
A
9
D
C
10
Dimension
Vogue Midi/
Vogue Midi
Midline
Vogue Midi T
3 Sided/ Vogue
Midi T Midline/
Highline
3 Sided
Vogue Midi T
3 Sided
Wall Mounted
A 150 200 200
B 225 225 400
C 150 200 200
D 50 50 0