Balanced Flue

18
Installation Instructions
Site Requirements
4. Optional Extra Flue Lengths and Bends
Nominal
Length
Actual
Length
Stainless
Finish
Anthracite
Finish
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
45° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
Optional Flue Collar 8548MB
5. Gas Supply
This appliance is intended for use on a gas installation with a
governed meter.
5.1 Before installation, ensure that the local distribution
conditions (identication of the type of gas and pressure) and
the adjustment of the appliance are compatible.
5.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
5.3 You can use soft copper tubing on the installation and soft
soldered joints outside the appliance and below the re.
5.4 A factory tted isolation device is part of the inlet connection;
no further isolation device is required.
5.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
5.6 The gas supply enters underneath the rear of the outer box:
5.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
6. Ventilation
6.1 This appliance requires no additional ventilation.
7. Appliance Location
7.1 This appliance has been designed to stand on either a
hearth or an optional bench:
Code Bench Width
RVACLB100B Riva Bench Low 1000mm
RVACB100B Riva Bench 1000mm
RVACLB120B Riva Bench Low 1200mm
RVACB120B Riva Bench 1200mm
RVACLB140B Riva Bench Low 1400mm
RVACB140B Riva Bench 1400mm
7.2 To Install the Bench:
Follow Section 1 Installation - All Models in Installation guide
PM205 supplied with the bench kit.
7.3 To secure the appliance to the bench:
You must consider where you place the appliance on the
bench before drilling the bench, see Diagram 6.
6
Once the position of the appliance has been decided:
Follow the instructions for securing the appliance on Page 21.
7.4 The non-combustible hearth must be at least 12mm thick,
and project a minimum of 50mm from the base of the
appliance in all directions.
7.5 The appliance is not suitable for installation against a
combustible wall. A combustible side wall must be a
minimum of 150mm (Vogue Midi / Midi Midline) or 200mm
(Vogue Midi T / Midline T/ Highline T 3 Sided) from the
appliance. This does not apply to wall mounted models.
7.6 This appliance can be installed with an up and out ue
(vertical wall - horizontal ue) or with a vertical ue with
roof termination (see Flue Options, Section 2 Site
Requirements).
HEARTH INSTALLATION
(NOT APPLICABLE FOR MIDLINE, HIGHLINE & WALL
MOUNTED MODELS)
7.7 Building Regulations state this appliance must stand on
a non-combustible hearth that is at least 12mm thick and
projects 50mm minimum from the base of the appliance in all
directions, however Gazco recommend the hearth extends to
the following dimensions, see Diagram 7.
C
A
B
7
Dimensions A B C
All Models 716mm 498mm 12mm