Balanced Flue
15
Installation Instructions
1. Flue and Chimney Requirements
Note: This appliance must only be installed with the ue
supplied.
You must adhere to the following:
1.1 The ue must be sited in accordance with BS5440: Part 1
(latest edition), see Diagram 1.
1.2 Fit a guard to protect people from any terminal less than 2
metres above any access such as level ground, a balcony or
above a at roof.
1.3 All horizontal ues must be securely xed and re
precautions followed in accordance with local and national
codes of practice.
1.4 A restrictor may be required. Refer to Technical
Specications on page 14.
Site Requirements
2. Timber Framed Buildings
2.1 To prevent a re hazard, you must provide additional
clearance when the appliance passes through a wall
containing any combustible materials.
2.2 A steel sleeve must be inserted into the hole through which
the ue passes to give an air gap of 25mm between the
sleeve and any outside surface of the ue.
2.3 Contact your local buildings authority for further guidance on
installing gas res in timber framed buildings.
Note: Make sure you provide adequate clearance at the
sides and back of the appliance for servicing access.
UK Dimensions
1
Dimension Terminal Position Minimum
Distance
A* Directly below an opening 600mm
B* Above an opening 300mm
C* Horizontally next to an opening 300mm
D Below gutters, soil pipes or drain pipe 300mm
E Below eaves 300mm
F Below balcony or car port roof 600mm
G From a vertical drain pipe or soil pipe 300mm
H From an internal or external corner or to a
boundary alongside the terminal
600mm
I Above ground, roof or balcony level 300mm
Dimension Terminal Position Minimum
Distance
J From a surface or boundary facing the
terminal
600mm
K From a terminal facing the terminal 600mm
L From an opening in the car port (e.g. door,
window) into the dwelling
1200mm
M Vertically from a terminal on the same wall 1200mm
N Horizontally from a terminal on the same
wall
300mm
P From a structure on the roof 600mm
Q Above the highest point of intersection with
the roof
300mm
* In addition, the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame.