Balanced Flue
10
Installation Instructions
Technical Specification
Covering the following models:
Model
Gas
CAT.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Vogue Midi /
Vogue Midi
Midline
I
2H
Natural (G20) 20mbar 2 x Ø7.5mm 063 0.457 4.8 2.5
GB, IE
I
3P
Propane (G31) 37mbar - 111 0.177 4.8 2.5
Vogue Midi T
3 Sided /
Vogue Midi T
Wall Mounted
3 Sided /
Vogue Midi
T Midline 3
Sided /
Vogue Midi
T Highline 3
Sided
I
2H
Natural (G20) 20mbar 2 x Ø8mm 440 0.543 5.7 3.5
I
3P
Propane (G31) 37mbar - 111 0.188 5.0 2.9
Rear Exit Wall Thickness - Min 200mm/ Max 550mm
Vogue Midi - Efciency Class 1 - 90.6%
Vogue Midi T - Efciency Class 1 - 94.3%
Flue Outlet Size ø 150mm, Flue Inlet Size ø 100mm
Gas Inlet Connection Size ø 8mm
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 2012 is 81.6% (Vogue Midi Models) & 84.9% (Vogue Midi T Models).
The test data has been certied by Kiwa Nederland B.V. The gross efciency value may be used in the UK Government's
Standard Assessment Procedure (SAP) for energy rating of dwellings.
MODEL VOGUE MIDI
VOGUE MIDI T
3 SIDED
VOGUE MIDI
MIDLINE
VOGUE MIDI T
MIDLINE 3 SIDED
VOGUE MIDI T
WALL MOUNTED
3 SIDED
VOGUE MIDI
T HIGHLINE 3
SIDED
Nat Gas 563-016 563-025 563-258 563-300 563-013 563-216
LPG 563-400 563-749 563-790 563-676 563-506 563-458