Conventional Flue

37
14. Primary Aeration Plate
NOTE: Not all models have aeration plates.
Please refer to the Technical Specication.
14.1 To replace the primary aeration plate turn off the gas supply
at the isolation device.
14.2 Remove the burner, see Installation Instructions, Replacing
Parts, Section 4.
14.3 Undo the 2 nuts and remove the plate.
14.4 Replace with the correct size plate and secure the 2 nuts.
Ensure that the lower edge of the plate is located over the
venturi ange, see Diagram 26.
26
15. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco
retailer for further information.
It will be necessary to change the following:
- Burner
- Injector
- Pilot Injector
- Gas Valve
Always quote the Model number and Serial number when
ordering any spare parts.
Servicing Instructions - Replacing Parts