Conventional Flue
22
Installation Instructions
5. Removing the Glass Door
IMPORTANT: THE OUTER PANELLING OF THE
GAZCO LOFT IS MADE FROM CAST IRON. USE
CAUTION WHEN INSTALLING, REMOVING AND
STORING AS THE COMPONENTS ARE HEAVY
AND SHOULD BE HANDLED CAREFULLY.
5.1 Remove the plinth to access the controls:
1. Pull the lower section of the plinth forward to release from
the studs.
2. Lift the top section and tilt forward to clear the hooks
and slots on the front of the appliance, see Diagram 28.
28
The glass door will need to be removed to gain access to the
fuel effect.
5.2 Remove the 4 screws, see Diagram 29.
29
5.3 Lift the glass door slightly and angle the bottom away from
the appliance. Lower the glass door to disengage the top
hooks from the appliance, see Diagram 30.
NOTE: SUPPORT DOOR WHEN REMOVING.
30
6. Gas Soundness Pressure Check
This is essential to expel any debris that may block the gas
controls.
6.1 Connect the gas to the 8mm elbow on the rear of the
appliance, see Diagram 31.
31
6.2 Connect a suitable pressure gauge to the test point located
on the inlet tting and turn the gas supply on. Light the
appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply
pressure is as stated on the databadge. Turn the gas off and
replace the test point screw, turn the gas on and check the
test point for leaks.