Conventional Flue
21
Installation Instructions
4. Installation of the Top Box
Rear Exit
4.1 Follow 4.5.
Top Exit
4.2 Remove the decorative ue collar, place carefully to one
side as this will need to be retted to the Top Extension
Section.
4.3 Remove the 2 screws from the back of the top cast plate,
see Diagram 23.
23
4.4 Remove the ue insert and cast top plate.
4.5 Remove the Top Box Section xing bracket from the
underside of the Top Section Box, see Diagram 24.
24
4.6 Fix bracket in the groove on the top of the appliance and
secure with a screw, see Diagram 25.
25
All Installations
4.7 Remove the 6 screws at the rear of the Top Box Section to
remove the back panel, see Diagram 26.
26
4.8 Lift the Top Box Section onto the appliance, ensuring the
sides are ush with the back of the appliance.
4.9 Secure at the front of the re by with 2 screws up through the
xing bracket and into the Top Box Section.
4.10 Replace the back panel of the Top Box, secure with 6
screws previously removed and 2 screws through the xing
holes at the back of the appliance which were used for the
cast top, see Diagram 27.
27
Top Exit only
4.11 Fit the decorative ue collar.
Rear Exit only
4.12 The spigot should be tted to the rear of the appliance.