Conventional Flue
15
Installation Instructions
MINIMUM CLEARANCE
5.8 The appliance is not suitable for installation against a
combustible wall.
5.9
Ensure that all minimum clearances to combustible
materials are complied with as shown in Diagrams 3 & 4.
The specied clearances provide the minimum distance to
combustible materials. If the appliance is intended to be
installed into a non-combustible opening the clearance to the
sides and above the appliance can be reduced. However, it
is recommended that the specied clearances are maintained
irrespective of the materials used in the construction of the
opening to allow adequate air ow and access to controls.
The clearance at the rear of the appliance must always be
a minimum of 50mm.
A
B
A
3
D
C
4
Dimension Loft
A 200
B 225
C 200
D 50
5.10 The above dimensions provide adequate clearance to
combustible materials. It may be necessary to add additional
clearance so that spillage tests can be performed when
necessary.
Site Requirements