Conventional Flue
13
Installation Instructions
Site Requirements
1. Flue & Chimney Requirements
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER
TO THE MANUFACTURERS INSTRUCTIONS.
1.1 The European chimney standards now describe chimneys
and flues by their temperature, pressure and resistance to
corrosion, condensation and fire. To identify the correct flue
system, the minimum flue specification is shown in the
Technical Specification. Existing chimneys are not covered
by this system.
1.2 The chimney or flue system must comply with the rules in
force, and must be a minimum of 127mm (5") in diameter.
1.3 A 5" (127mm) liner must be used if fitting the appliance into
an existing brick built chimney.
Larger lined flues can work, but in some instances could
cause cold start flue problems resulting in nuisance
shutdown. Lined flues above 7" (175mm) are not
recommended.
Suitable systems are:
a) Flexible liner which must be continuous from the
appliance spigot to the roof terminal.
b) Gazco Linerless kit.
UNDER NO CIRCUMSTANCES MUST THE LINERLESS
KIT BE USED WITH ANY INSTALLATION OTHER THAN
AN EXISTING MASONRY CHIMNEY WHICH HAS A
MINIMUM DIAMETER OF 178mm (7”). THE CHIMNEY
MUST BE SOUND AND CLEAN. IF PREVIOUSLY USED
FOR SOLID FUEL, IT MUST BE SWEPT PRIOR TO
PROCEEDING WITH THE INSTALLATION.
NOTE: If the Linerless kit is to be used, due care should be
taken to prevent condensation forming in the chimney. Do
not fit the Linerless Kit if the chimney is taller than 10 metres
(external wall) or 12 metres (internal wall).
1.4 The minimum flue height for the appliance must be 3 metres
(10ft). Any horizontal flue run from the rear outlet must not
exceed 100mm from the back of the appliance.
1.5 The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
1.6 The chimney must be swept prior to the installation, but it
need not be swept if it can be seen the chimney is clean
and unobstructed throughout its entire length.
Steel Register
Plate with Clamp
that holds the Flex
Adapter
Flex Pipe Adapter
connects to stove
ue pipe
Stove Flue Pipe
running from the
stove to the Flex
Pipe Adapter
Stove
1
2. Flue Options
2.1 Consult the rules in force.
NOTE: This appliance does not normally require any
additional ventilation when installed in GB.
A range of Vitreous Enamel Gloss Black ue pipe is
available to compliment the appliance. Please contact
your Gazco retailer for further information.