Balanced Flue

45
Servicing Instructions - Replacing Parts
14. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco retailer
for further information.
It will be necessary to replace the following components:
- Top Bafe
- Burner
- Injector
- Pilot Injector
- Gas Valve
Always quote the Model number and Serial number when
ordering any spare parts.
15. Control Upgrade
See Installation Instructions, Section 2.
16. Explosion Relief Gasket
IMPORTANT: If it is required to access the rear
explosion relief for servicing the appliance must rst
be removed from the wall.
16.1 It is possible to change the gasket on the explosion relief
panel.
Rear Explosion Relief
16.2 Remove the 6 screws on each spring panel and the 4 from
the centre bracket.
28
Rear of Appliance Rear Explosion Relief
16.3 Remove the gasket and replace.
Ensure when replacing that the springs are located into the
recess.
16.4 Refit in reverse order.
Lower Explosion Relief
16.5 Remove the 5 screws on each spring panel, see Diagram 29.
29
Underside of
Appliance Lower
Explosion Relief
16.6 Remove the gasket and replace.
Ensure when replacing that the springs are located into the
recess.
16.7 Refit in reverse order.