12. Glass Side Panels
12.1 Remove the glass door, see Section 2.
12.2 Remove the plinth:
1. Pull the lower section of the plinth forward to release from
the studs.
2. Lift the top section and tilt forward to clear the hooks
and slots on the front of the appliance, see Diagram 24.
24
12.3 Remove the 2 side screws, see Diagram 25.
Screws
25
12.4 Pull the front of the side panels away from the appliance
and slide backwards to disengage the back tabs, see
Diagram 25.
12.5 Hold the glass panel carefully and slide towards the back of
the appliance to disengage from the slots in the side of the
carcass, see Diagram 26 (1).
26
1
1
2
2
12.6 Angle the glass side panels away from the appliance to
disengage the slots, see Diagram 26 (2).
12.7 Replace the glass and gasket, ensuring that the printed side
is facing outwards.
To replace the Glass Side Panels:
12.8 Locate the tabs on the panel into the slots on the sides of the
appliance and slide forward until it stops, see Diagram 26.
13. Primary Aeration Plate
NOTE: Not all models have aeration plates.
Please refer to the Technical Specication.
13.1 To replace the primary aeration plate turn off the gas supply
at the isolation device.
13.2 Remove the burner, see Installation Instructions, Replacing
Parts, Section 4.
13.3 Undo the 2 nuts and remove the plate.
13.4 Replace with the correct size plate and secure the 2 nuts.
Ensure that the lower edge of the plate is located over the
venturi ange, see Diagram 27.
27
Servicing Instructions - Replacing Parts