Balanced Flue
29
6.29 TAKE CARE TO MARK OUT THE FLUE CORRECTLY. IT
IS DIFFICULT TO MOVE AFTER INSTALLATION.
6.30 Create a 152mm (6”) diameter hole for the ue using either:
a) a core drill, or
b) a hammer and chisel
6.31 Make good at both ends of the hole.
Flue Length
6.32 The nal length of the ue pipe includes the terminal. The
terminal is the only section that can be shortened.
DO NOT SHORTEN ANY OTHER SECTION OF FLUE PIPE.
6.33 Measure from the outside of the wall to the stop on the
90° elbow.
6.34 Fit horizontal ue section between the elbow and the
terminal at this stage, if required, see Diagram 42.
10mm
Wall plate
42
6.35 Mark the correct length all the way around the ue terminal
section, see Diagram 43.
6.36 Insert the square cardboard sleeve into the ue to support
the inner tube.
6.37 Cut through the ue and sleeve, see Diagram 43.
43
6.38
REMOVE THE CARDBOARD REMNANTS FROM THE FLUE.
6.39 File the cut edge smooth.
Installation Instructions
Flue and Appliance Fixings
6.40 Pull appliance and ue assembly away from the hearth.
6.41 Drill 4 xing holes for the wall plate and insert wall
plugs supplied.
6.42 Put the horizontal ue onto the elbow and reposition the
appliance.
6.43 Check the ue runs smoothly through the wall.
6.44 Fix the wall plate to the wall using the 4 black screws
provided.
6.45 Drill through the xing tab of the wall plate using a
3.5mm drill.
6.46 Secure with the screw provided.
6.47 Make good and weatherproof around the outside of the ue.
6.48 Replace the Top Extension Section back panel:
Locate the back panel under the top of the Top Extension
Section and position so it sits ush with the casting.
44
6.49 Secure with the screws previously removed.