Balanced Flue

18
Installation Instructions
Site Requirements
7.8 If installing on a studwork wall it is essential that
the battens are located in the xing area for the wall
mounting bracket, see Diagram 7.
7
MOUNTING BRACKET DIMENSIONS
8
53
3
129
411
295
129
62
523
119
300
(Centre)
304
(Centre)
54
266
535
300
(Centre)
304
(Centre)
7.9 DISTANCE FROM FLOOR / HEARTH LEVEL
It is necessary to leave a minimum gap of 100mm
below the base of the wall mounted appliance to ensure
servicing access.
MINIMUM CLEARANCE
7.10 Freestanding appliances are not suitable for installation
against a combustible wall.
(NOT APPLICABLE FOR WALL MOUNTED MODELS.)
7.11 Ensure that all minimum clearances to combustible
materials are complied with, see Diagrams 9 & 10.
The specied clearances provide the minimum distance to
combustible materials. If the appliance is intended to be
installed into a non-combustible opening the clearance to the
sides and above the appliance can be reduced. However, it
is recommended that the specied clearances are maintained
irrespective of the materials used in the construction of the
opening to allow adequate air ow and access to controls.
The clearance at the rear of the appliance must always
be a minimum of 50mm (NOT APPLICABLE FOR WALL
MOUNTED MODELS).
A
B
A
9
C
10
Dimension
Loft
Freestanding
Installation
Loft
Wall Mounted
Installation
A 150 150
B 225 400
C 50 0