Balanced Flue
18
Installation Instructions
Site Requirements
7.8 If installing on a studwork wall it is essential that
the battens are located in the xing area for the wall
mounting bracket, see Diagram 7.
7
MOUNTING BRACKET DIMENSIONS
8
53
3
129
411
295
129
62
523
119
300
(Centre)
304
(Centre)
54
266
535
300
(Centre)
304
(Centre)
7.9 DISTANCE FROM FLOOR / HEARTH LEVEL
It is necessary to leave a minimum gap of 100mm
below the base of the wall mounted appliance to ensure
servicing access.
MINIMUM CLEARANCE
7.10 Freestanding appliances are not suitable for installation
against a combustible wall.
(NOT APPLICABLE FOR WALL MOUNTED MODELS.)
7.11 Ensure that all minimum clearances to combustible
materials are complied with, see Diagrams 9 & 10.
The specied clearances provide the minimum distance to
combustible materials. If the appliance is intended to be
installed into a non-combustible opening the clearance to the
sides and above the appliance can be reduced. However, it
is recommended that the specied clearances are maintained
irrespective of the materials used in the construction of the
opening to allow adequate air ow and access to controls.
The clearance at the rear of the appliance must always
be a minimum of 50mm (NOT APPLICABLE FOR WALL
MOUNTED MODELS).
A
B
A
9
C
10
Dimension
Loft
Freestanding
Installation
Loft
Wall Mounted
Installation
A 150 150
B 225 400
C 50 0