Balanced Flue
40
3.5 To remove the side trim lift and hook off the rebox, see
Diagram 11.
NOTE: The Side Trims only need to be removed if
damaged or the side glass needs replacing.
11
4. Main Burner
To replace the main burner:
4.1 Remove the 2 securing screws at the front of the burner, see
Diagram 12.
12
4.2 Lift the burner out of the rebox at an angle clear the
brackets, exposing the service hatch, see Diagram 13.
13
Service
Hatch
Screws
4.3 Ret in reverse order.
Important: Ensure the burner engages with the injector at the
base of the rebox, see Diagram 14.
Injector
14
5. Control Assembly & Service Hatch
5.1 It is not necessary to remove the complete control assembly
to service or replace parts of this appliance. The following
sections will detail how to individually remove and replace
each element.
5.2 The Loft has a servicing hatch to allow access to the gas
valve and control assembly in the base of the rebox.
Remove the 4 screws holding the service hatch,
see Diagram 15.
Remove the panel.
5.3 This will allow access to the rear of the valve, see Diagram 15.
15
Gas Valve
Pilot Pipe
Mag
Unit
Interruptor
Leads
5.4 Reposition the service hatch and tighten the 4 screws, see
Diagram 16.
16
Ceramic Gasket
face down
Servicing Instructions - Replacing Parts