Balanced Flue

13
Installation Instructions
Technical Specification
This appliance has been certified for use in countries other than
those stated. To install this appliance in these countries, it is
essential to obtain the translated instructions and in some cases
the appliance will require modification. Contact Gazco for further
information.
PACKING CHECKLIST
ALL MODELS
Qty Description Fixing Kit containing:-
1 x Loft Appliance
1 x Log Set (4 Logs)
1 x Lining Set
All Models:
2 x No.8 Red Rawl Plugs
1 x Battery Holder
1 x Embaglow Packet
1 x instructions
2 x No.8 Screw
4 x AA Batteries
1 x 9v Battery
1 x 70mm Restrictor
Graphite Metal Plinth Only:
3 x M5x25 Hex Head Screws
To Extension Section Only:
4 x No.8 x 10 Screws
Stone Plinth & Log Store Only:
4 x Metal Rawl Plug
4 x No.6 x 40 Coach Screw
4 x 32mm Felt Pad
LOFT RANGE
RESTRICTOR REQUIREMENT - NAT GAS/ LPG
VERTICAL & HORIZONTAL FLUE TOP EXIT - VERTICAL ONLY INCLUDING OFFSET
Vertical Flue Height Horizontal Length Restrictor Size Vertical Flue Height Restrictor Size
500mm - 999mm 250mm - 1000mm No restrictor 2000mm - 4999mm Ø 52mm
1000mm - 1499mm 250mm - 1000mm Ø 70mm 5000mm - 10,000mm Ø 47mm
1500mm - 3000mm 250mm - 5000mm Ø 60mm