Datasheet

5
Acer AT150 F1 Specifications
Technical Specifications
Dimensions
(with bezel)
Form factor
System inlet
temperature
Operating
10° - 35° C (50° - 95° F) at sea level with an
altitude derating of 1° C per 305 m (1.8° F per
1000 ft.) above sea level to a maximum of 3050 m
(10,000 ft.) no direct sustained sunlight.
Maximum rate of change is 10°C/hr.
(18°F/hr.). The upper limit depends on the
type and number of options installed. System
performance may be reduced if operating with
a fan fault or above 30°C (86°F).
Non-operating
-40° - 70° C (-40° - 158° F) Maximum rate of
change is 20°C/hr. (36°F/hr.).
Relative humidity
(non-condensing)
Operating
8 - 90 % relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-condensing
Non-operating
5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing