5 The Alert Policy Table lets you group alert destinations. In this table, alert destinations are
placed into the Destination Selector fields and group numbers are placed into the Policy
Number fields. For example, if group policy 1 is selected, alerts are sent to both alert
destinations 1 and 2. If group policy 2 is selected, an alert is only sent to alert destination
1, and so forth.
After configuring Alert Policy Groups, return to the Monitoring Sensors page (see
“Monitoring sensors and setting PEFs (platform event flags)” on page 4), then:
a Choose a sensor that you want to trigger an SNMP alert (by clicking the sensor’s PEF
button).
b Select Send Alert for the PEF Action.
c Enable the PEF Control by selecting Enabled from the list.
d Choose the appropriate Alert Policy Group from the drop down list, then click Add.
In this illustration you can choose No Alert Policy, Alert Policy 1, Alert Policy 2,
Alert Policy 3, or Alert Policy 4.