User's Manual Part 2
ExitManager
G
ATEKEEPER SYSTEMS INC.
2007
CART CONTAINMENT MANUAL
Page 57
ExitManager Settings
ExitManager can be configured to generate a signal for a Standard Outdoor GS
1
application, a Standard Indoor
GS1 application, or a Standard Indoor Purchek application, based on the settings of the Signal Selector switches
shown in the tables below.
Selector Switch
Settings:
1 ▲ 2 ▲ 3 ▼ 4 ▼ 5 ▼ 6 ▼
Outdoor GS
2
Application
(One locking line)
Cable Termination Settings:
• Locking Antenna terminates at the “Register Line” Loop Connector
• Jumper Is Inserted into the Cable Inputs at the “Door Line” Loop
Connector
Rotary Switch Setting: 1
Selector Switch
Settings:
1 ▲
2 ▼
3 ▲ 4 ▼ 5 ▼ 6 ▼
Indoor GS
2
Application
(One lock line and one
unlock line)
Cable Termination Settings:
• Locking Antenna terminates at the “Register Line” Loop Connector
• Unlocking Antenna Terminates at the “Door Line” Loop Connector
Rotary Switch Setting: 0
Selector Switch
Settings:
1 ▼ 2 ▼ 3 ▼
4 ▼ 5 ▼ 6 ▼
Indoor Purchek
Application
Cable Termination Settings:
• Locking Antenna terminates at the “Door Line” Loop Connector
• Unlocking Antenna Terminates at the “Register Line” Loop Connector
Rotary Switch Settings to set Entry Permission Timings (Setting – Timing)
• 0 - 2 minutes
• 1 - 15 minutes
• 2 - 10 minutes
• 3 - 30 minutes
• 4 - 1 hour
• 5 - 3 hours
• 6 - 2 hours
• 7 - 1 minute