Section 4: Installation Practices
a) Pad Mounted Equipment (Fig. 4-73) – Moveable gas appliances on concrete pads or blocks, such as heat pumps,
air conditioners, pool heaters and NGV refueling systems, shall be connected to the FlashShield™ CSST system at a
termination fitting using either rigid pipe or an approved outdoor appliance connector.
b) Gas Packs and Other Non-Moveable Equipment (Fig. 4-74) – Can be connected to the FlashShield™ CSST system either
through a terminating fitting and rigid pipe or directly with FlashShield™ CSST connected to the appliance shut-off valve.
c) Gas Lamps – Permanently mounted lights located on
decks shall be connected to the FlashShield™ CSST
system in the same fashion as permanently mounted
grills as shown in the figure and in accordance with the
manufacturers instructions.
d) Yard Mounted Lights – Shall be connected to the
FlashShield™ CSST system as shown in Figure 4-75.
All FlashShield™ CSST installed below grade shall be
installed in accordance with Section 4.9.