Section 4: Installation Practices
4.6.2 Direct Connection – Non-Moveable Appliances
FlashShield™ CSST may be connected directly to non-
movable appliances such as water heaters, furnaces, boilers and
island cook-tops (Figures 4-65) without the installation of a
termination outlet or flexible appliance connector. All local codes
requiring drip legs and shut-off valves must be observed. Drip
legs and shut-off valves must be securely mounted. Additionally,
FlashShield™ should not penetrate metallic cabinet of appliance.
4.6.3 Gas Convenience Outlet
a) Barbecue Grills – Movable grills shall be connected using an approved outdoor appliance connector which shall be attached
to the CSST system either at a termination fitting or a quick disconnect device as shown in the figure (Fig. 4-66).
b) Permanently mounted grills located on decks (Fig. 4-67) shall be connected to the CSST system as shown in the figure
and in accordance with the manufacturer’s instructions. e outdoor portion of the CSST run shall be supported against
the side of any of the inside deck joists.
Fig. 4-65
Fig. 4-67Fig. 4-66
Note: Strike Protection
(Floppy) not shown for clarity.