Fig. 3-14
Section 3: System Configuration
3.2.7 Example 6 - Series System – 7"WC - Hybrid
Figure 3-14 below shows a typical single-family house retrofit installation with five (5) appliances, 2 of which are added
onto an existing black pipe system. e piping is arranged in series with a main run branching at the appliances. e utility
companys supply pressure (downstream of the meter) is 7"WC. e utility company advises that the specific gravity of the
gas delivered will be 0.60 and the energy content is 1 CFH = 1000 BTUH. e allowable pressure drop across the system
has been determined to be 2.0"WC (supply pressure 7"WC - appliance requirement 5"WC).
Note: Rigid pipe sized using a 0.5"WC pressure drop table, as no 2.0"WC pressure drop table for Rigid pipe is available.
Table 3-7
Section Description Load Delivered by Section Section Length Run Length Tube Size
A” – Rigid Trunk 221 CFH = 221,000 BTUH 40 feet 70 feet 1" Rigid
“B” – Rigid Trunk 141 CFH = 140,000 BTUH 5 feet 70 feet 1" Rigid
“C” – Rigid Trunk 105 CFH = 105,000 BTUH 10 feet 70 feet 3/4" Rigid
“D” – CSST Trunk 53 CFH = 53,000 BTUH 10 feet 70 feet 1/2" CSST
“E” – BBQ 25 CFH = 25,000 BTUH 5 feet 70 feet 1/2" CSST
“F” – Furnace 80 CFH = 80,000 BTUH 10 feet 50 feet 3/4" Rigid
“G” – Water Heater 36 CFH = 36,000 BTUH 10 feet 55 feet 3/8" Rigid
“H” – Range 52 CFH = 52,000 BTUH 10 feet 65 feet 1/2" Rigid
“J” – Dryer 28 CFH = 28,000 BTUH 5 feet 70 feet 1/2" CSST
Run Length for Trunk Sections = Distance from meter to furthest appliance (Longest Run)
Run Length for Appliance Sections = Distance from meter to each appliance
SIZING RUN “A”
Run “A” is sized by the total load of all appliances and the run length from the meter to the furthest appliance
e total load of all appliances is 80 + 36 + 52 + 28 + 25 = 221CFH
e run length to the BBQ (furthest appliance) is 40 + 5 + 10 + 10 + 5 = 70ft
Referring to Table 7-23 (Rigid pipe 0.5"WC pressure drop): for a 70ft run, 1" Rigid pipe has a capacity over 221CFH
(actual: 240)
SIZING RUN “B”
Run “B” is sized by the total load of all supplied appliances and the run length from the meter to the furthest appliance
e total load of the supplied appliances is 36 + 52 + 28 + 25 = 141CFH
e run length to the BBQ (furthest appliance) is 40 + 5 + 10 + 10 + 5 = 70ft
Referring to Table 7-23 (Rigid pipe 0.5"WC pressure drop) for a 70ft run, 1" Rigid pipe has a capacity over 141CFH
(actual: 240)