Brochure
Gastite Division, Titeflex Corporation
1116 Vaughn Parkway / Portland, TN 37148
800.662.0208 / www.gastite.com / gastite@gastite.com
26
April 2015
Section 3: System Configuration
SIZING RUN “C”
• Run “C” is sized by the load of the supplied appliance and the run length to the supplied appliance
• e load of the water heater is 36CFH
• e run length to the water heater is 10ft
• Referring to Table 7-5 (3.0"WC pressure drop) for a 10ft run, 3/8" CSST has a capacity over 36CFH (actual: 83)
SIZING RUN “D”
• Run “D” is sized by the load of the supplied appliance and the run length to the supplied appliance
• e load of the range is 52CFH
• e run length to the range is 20ft
• Referring to Table 7-5 (3.0"WC pressure drop) for a 20ft run, 3/8" CSST has a capacity over 52CFH (actual: 58)
SIZING RUN “E”
• Run “E” is sized by the total load of all supplied appliances and the run length from the regulator to the furthest appliance
• e total load of the BBQ and the dryer is 25 + 28 = 53CFH
• e run length to the BBQ (furthest appliance) is 20 + 5 = 25ft
• Referring to Table 7-5 (3.0"WC pressure drop) for a 25ft run, 1/2" CSST has a capacity over 53CFH (actual: 144)
SIZING RUN “F”
• Run “F” is sized by the load of the supplied appliance and the run length to the supplied appliance
• e load of the dryer is 28CFH
• e run length to the dryer is 20 + 5 = 25ft
• Referring to Table 7-5 (3.0"WC pressure drop) for a 25ft run, 3/8" CSST has a capacity over 28CFH (actual: 51)
SIZING RUN “G”
• Run “G” is sized by the total load of the supplied appliance and the run length from the regulator to the furthest appliance
• e load of the BBQ is 25CFH
• e run length to the BBQ is 20 + 5 = 25ft